Debuged: checks minimum number of zero crossings before calculating source spectrum from P pulse.
This commit is contained in:
parent
dc088509d4
commit
a1fbea98be
@ -11,7 +11,6 @@ function conglomerate utils.
|
||||
|
||||
import matplotlib.pyplot as plt
|
||||
import numpy as np
|
||||
import pdb
|
||||
from scipy import integrate
|
||||
from pylot.core.pick.Picker import AICPicker, PragPicker
|
||||
from pylot.core.pick.CharFuns import HOScf, AICcf, ARZcf, ARHcf, AR3Ccf
|
||||
@ -332,7 +331,7 @@ def autopickstation(wfstream, pickparam):
|
||||
# calculate spectrum using only first cycles of
|
||||
# waveform after P onset!
|
||||
zc = crossings_nonzero_all(wfzc)
|
||||
if np.size(zc) == 0:
|
||||
if np.size(zc) == 0 or len(zc) <= 3:
|
||||
print ("Something is wrong with the waveform, "
|
||||
"no zero crossings derived!")
|
||||
print ("Cannot calculate source spectrum!")
|
||||
|