[bugfix] small workaround, will still cause error in case Z-component ist tilted by more than 5deg
before: wfdat[0] was using HHE component of previously rotated stream, which could not be found in metadata (dataless fname still HH2)
This commit is contained in:
parent
0995350697
commit
dfc9de69de
@ -251,6 +251,7 @@ def autopickstation(wfstream, pickparam, verbose=False,
|
||||
Ao = None # Wood-Anderson peak-to-peak amplitude
|
||||
picker = 'auto' # type of picks
|
||||
|
||||
# TODO: REMOVE HARDCODED CHANNEL MAPPING
|
||||
# split components
|
||||
zdat = wfstream.select(component="Z")
|
||||
if len(zdat) == 0: # check for other components
|
||||
@ -298,7 +299,7 @@ def autopickstation(wfstream, pickparam, verbose=False,
|
||||
if not metadata:
|
||||
print('Warning: Could not use TauPy to estimate onsets as there are no metadata given.')
|
||||
else:
|
||||
station_id = wfstream[0].get_id()
|
||||
station_id = zdat[0].get_id()
|
||||
station_coords = metadata.get_coordinates(station_id, time=wfstream[0].stats.starttime)
|
||||
if station_coords and origin:
|
||||
source_origin = origin[0]
|
||||
|