2022-11-03 15:39:23 +01:00
# Parameters file for Surveillance Bot
2022-12-06 15:43:13 +01:00
datapath : "/data/SDS/" # SC3 Datapath
networks : [ "1Y" , "HA" ] # select networks, list or str
stations : "*" # select stations, list or str
locations : "*" # select locations, list or str
channels : [ "EX1" , "EX2" , "EX3" , "VEI" , "LCQ" ] # Specify SOH channels, currently supported EX[1-3], VEI, LCQ
channel_names : [ "Clock Quality (%)" , "Temperature (°C)" , "230V/12V Status (V)" , "Router/Charger State (V)" , "Logger Voltage (V)" ] # names for plotting (optional)
2022-11-22 13:34:58 +01:00
stations_blacklist : [ "TEST" , "EREA" ]
2022-11-03 15:39:23 +01:00
networks_blacklist : [ ]
2022-11-21 10:35:15 +01:00
interval : 60 # Perform checks every x seconds
2022-12-06 15:31:09 +01:00
n_track : 300 # wait n_track * intervals before performing an action (i.e. send mail/end highlight status)
2022-11-23 11:28:36 +01:00
timespan : 7 # Check data of the recent x days
2022-12-02 11:15:01 +01:00
verbosity : 0 # verbosity flag
2022-11-03 15:39:23 +01:00
track_changes : True # tracks all changes since GUI startup by text highlighting (GUI only)
2022-12-06 15:31:09 +01:00
warn_count : False # show number of warnings and errors in table
min_sample : 3 # minimum samples for raising Warn/FAIL
2022-11-08 16:45:21 +01:00
dt_thresh : [ 300 , 1800 ] # threshold (s) for timing delay colourisation (yellow/red)
2022-11-09 14:32:13 +01:00
html_figures : True # Create html figure directory and links
2022-11-21 10:35:15 +01:00
reread_parameters : True # reread parameters file (change parameters on runtime, not for itself/GUI refresh/datapath)
2022-11-03 15:39:23 +01:00
POWBOX :
pb_ok : 1 # Voltage for PowBox OK
pb_SOH2 : # PowBox channel 2 voltage translations
2022-11-14 22:31:22 +01:00
-1 : {"230V": "PBox under 1V", "12V": "PBox under 1V" }
2022-11-22 13:34:58 +01:00
1 : {"230V": "OK", "12V": "OK" }
2022-11-03 15:39:23 +01:00
2 : {"230V": "OFF", "12V": "OK" }
3 : {"230V": "OK", "12V": "overvoltage" }
4 : {"230V": "OK", "12V": "undervoltage" }
4.5 : {"230V": "OFF", "12V": "overvoltage" }
5 : {"230V": "OFF", "12V": "undervoltage" }
pb_SOH3 : # PowBox channel 3 voltage translations
2022-11-14 22:31:22 +01:00
-1 : {"router": "PBox under 1V", "charger": "PBox under 1V" }
2022-11-03 15:39:23 +01:00
1 : {"router": "OK", "charger": "OK" }
2 : {"router": "OK", "charger": "0 < resets < 3" }
2.5 : {"router": "OK", "charger": "locked" }
3 : {"router": "FAIL", "charger": "OK" }
4 : {"router": "FAIL", "charger": "0 < resets < 3" }
5 : {"router": "FAIL", "charger": "locked" }
2022-11-17 09:52:04 +01:00
# Thresholds for program warnings/voltage classifications
2022-11-03 15:39:23 +01:00
THRESHOLDS :
pb_thresh : 0.2 # Threshold for PowBox Voltage check +/- (V)
max_temp : 50 # max temperature for temperature warning
low_volt : 12 # min voltage for low voltage warning
high_volt : 14.8 # max voltage for over voltage warning
unclassified : 5 # min voltage samples not classified for warning
2022-12-06 15:43:13 +01:00
clockquality_warn : 90 # clock quality ranges from 0 % to 100 % with 100 % being the best level
clockquality_fail : 70
2022-11-17 09:52:04 +01:00
2022-12-02 11:15:01 +01:00
# ---------------------------------------- OPTIONAL PARAMETERS ---------------------------------------------------------
2022-11-22 14:20:22 +01:00
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
add_links :
2022-12-02 11:15:01 +01:00
# for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
slmon : {"URL": "../slmon/{nw}_{st}.html", "text": "show" }
2022-11-29 10:42:29 +01:00
24h-plot : {"URL": "../scheli/{nw}/{st}.png", "text": "plot" }
2022-11-22 14:20:22 +01:00
2022-12-02 11:15:01 +01:00
# E-mail notifications
2022-11-17 09:52:04 +01:00
EMAIL :
2022-11-22 13:34:58 +01:00
mailserver : "localhost"
addresses : [ "marcel.paffrath@rub.de" , "kasper.fischer@rub.de" ] # list of mail addresses for info mails
sender : "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
2022-11-17 09:52:04 +01:00
2022-12-02 11:15:01 +01:00
# names for plotting of the above defined parameter "channels" in the same order
channel_names : [ "Temperature (°C)" , "230V/12V Status (V)" , "Router/Charger State (V)" , "Logger Voltage (V)" ]
# specify y-ticks (and ylims) giving, (ymin, ymax, step) for each of the above channels (0: default)
CHANNEL_TICKS :
- [ -10 , 50 , 10 ]
- [ 1 , 5 , 1 ]
- [ 1 , 5 , 1 ]
- [ 9 , 15 , 1 ]
# Factor for channel to SI-units (for plotting)
2022-11-21 15:31:32 +01:00
CHANNEL_UNITS :
EX1 : 1e-6
EX2 : 1e-6
EX3 : 1e-6
VEI : 1e-3
# Transform channel for plotting, perform arithmetic operations in given order, e.g.: PBox EX1 V to deg C: 20 * x -20
CHANNEL_TRANSFORM :
EX1 :
2022-11-22 13:34:58 +01:00
- [ "*" , 20 ]
2022-12-02 11:15:01 +01:00
- [ "-" , 20 ]