survBot/parameters.yaml

71 lines
3.1 KiB
YAML
Raw Normal View History

# Parameters file for Surveillance Bot
2022-11-22 13:34:58 +01:00
datapath: "/data/SDS/" # SC3 Datapath
networks: ["1Y", "HA"]
stations: "*"
locations: "*"
channels: ["EX1", "EX2", "EX3", "VEI"] # Specify SOH channels, currently supported EX[1-3] and VEI
2022-11-22 14:20:22 +01:00
channel_names: ["Temperature (°)", "Voltage (V)", "Voltage (V)", "Voltage (V)"] # names for plotting (optional)
2022-11-22 13:34:58 +01:00
stations_blacklist: ["TEST", "EREA"]
networks_blacklist: []
2022-11-21 10:35:15 +01:00
interval: 60 # Perform checks every x seconds
n_track: 120 # wait number of intervals after FAIL before performing an action (i.e. send mail)
timespan: 3 # Check data of the recent x days
verbosity: 0
track_changes: True # tracks all changes since GUI startup by text highlighting (GUI only)
warn_count: False # show number of warnings and errors in table
dt_thresh: [300, 1800] # threshold (s) for timing delay colourisation (yellow/red)
html_figures: True # Create html figure directory and links
2022-11-21 10:35:15 +01:00
reread_parameters: True # reread parameters file (change parameters on runtime, not for itself/GUI refresh/datapath)
POWBOX:
pb_ok: 1 # Voltage for PowBox OK
pb_SOH2: # PowBox channel 2 voltage translations
-1: {"230V": "PBox under 1V", "12V": "PBox under 1V"}
2022-11-22 13:34:58 +01:00
1: {"230V": "OK", "12V": "OK"}
2: {"230V": "OFF", "12V": "OK"}
3: {"230V": "OK", "12V": "overvoltage"}
4: {"230V": "OK", "12V": "undervoltage"}
4.5: {"230V": "OFF", "12V": "overvoltage"}
5: {"230V": "OFF", "12V": "undervoltage"}
pb_SOH3: # PowBox channel 3 voltage translations
-1: {"router": "PBox under 1V", "charger": "PBox under 1V"}
1: {"router": "OK", "charger": "OK"}
2: {"router": "OK", "charger": "0 < resets < 3"}
2.5: {"router": "OK", "charger": "locked"}
3: {"router": "FAIL", "charger": "OK"}
4: {"router": "FAIL", "charger": "0 < resets < 3"}
5: {"router": "FAIL", "charger": "locked"}
# Thresholds for program warnings/voltage classifications
THRESHOLDS:
pb_thresh: 0.2 # Threshold for PowBox Voltage check +/- (V)
max_temp: 50 # max temperature for temperature warning
low_volt: 12 # min voltage for low voltage warning
high_volt: 14.8 # max voltage for over voltage warning
unclassified: 5 # min voltage samples not classified for warning
2022-11-22 14:20:22 +01:00
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
# optional!
add_links:
slmon: {"URL": "{nw}_{st}.html", "text": "show"} # for example: slmon: {"URL": "{nw}_{st}.html", "text": "link"}
# E-mail notifications (optional)
EMAIL:
2022-11-22 13:34:58 +01:00
mailserver: "localhost"
addresses: ["marcel.paffrath@rub.de", "kasper.fischer@rub.de"] # list of mail addresses for info mails
sender: "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
2022-11-22 14:20:22 +01:00
# Factor for channel to SI-units (for plotting, optional)
CHANNEL_UNITS:
EX1: 1e-6
EX2: 1e-6
EX3: 1e-6
VEI: 1e-3
# Transform channel for plotting, perform arithmetic operations in given order, e.g.: PBox EX1 V to deg C: 20 * x -20
2022-11-22 14:20:22 +01:00
# optional!
CHANNEL_TRANSFORM:
EX1:
2022-11-22 13:34:58 +01:00
- ["*", 20]
- ["-", 20]