release/1.0 #3
@ -1,16 +1,15 @@
|
||||
# Parameters file for Surveillance Bot
|
||||
datapath: "/data/SDS/" # SC3 Datapath
|
||||
networks: ["1Y", "HA"]
|
||||
stations: "*"
|
||||
locations: "*"
|
||||
datapath: "/data/SDS/" # SC3 Datapath
|
||||
networks: ["1Y", "HA"] # select networks, list or str
|
||||
stations: "*" # select stations, list or str
|
||||
locations: "*" # select locations, list or str
|
||||
channels: ["EX1", "EX2", "EX3", "VEI"] # Specify SOH channels, currently supported EX[1-3] and VEI
|
||||
channel_names: ["Temperature (°C)", "230V/12V Status (V)", "Router/Charger State (V)", "Logger Voltage (V)"] # names for plotting (optional)
|
||||
stations_blacklist: ["TEST", "EREA"]
|
||||
networks_blacklist: []
|
||||
stations_blacklist: ["TEST", "EREA"] # exclude these stations
|
||||
networks_blacklist: [] # exclude these networks
|
||||
interval: 60 # Perform checks every x seconds
|
||||
n_track: 120 # wait n_track * intervals before performing an action (i.e. send mail/end highlight status)
|
||||
timespan: 7 # Check data of the recent x days
|
||||
verbosity: 0
|
||||
verbosity: 0 # verbosity flag
|
||||
track_changes: True # tracks all changes since GUI startup by text highlighting (GUI only)
|
||||
warn_count: False # show number of warnings and errors in table
|
||||
dt_thresh: [300, 1800] # threshold (s) for timing delay colourisation (yellow/red)
|
||||
@ -44,20 +43,31 @@ THRESHOLDS:
|
||||
high_volt: 14.8 # max voltage for over voltage warning
|
||||
unclassified: 5 # min voltage samples not classified for warning
|
||||
|
||||
# ---------------------------------------- OPTIONAL PARAMETERS ---------------------------------------------------------
|
||||
|
||||
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
|
||||
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
|
||||
# optional!
|
||||
add_links:
|
||||
slmon: {"URL": "../slmon/{nw}_{st}.html", "text": "show"} # for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
|
||||
# for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
|
||||
slmon: {"URL": "../slmon/{nw}_{st}.html", "text": "show"}
|
||||
24h-plot: {"URL": "../scheli/{nw}/{st}.png", "text": "plot"}
|
||||
|
||||
# E-mail notifications (optional)
|
||||
# E-mail notifications
|
||||
EMAIL:
|
||||
mailserver: "localhost"
|
||||
addresses: ["marcel.paffrath@rub.de", "kasper.fischer@rub.de"] # list of mail addresses for info mails
|
||||
sender: "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
|
||||
|
||||
# Factor for channel to SI-units (for plotting, optional)
|
||||
# names for plotting of the above defined parameter "channels" in the same order
|
||||
channel_names: ["Temperature (°C)", "230V/12V Status (V)", "Router/Charger State (V)", "Logger Voltage (V)"]
|
||||
# specify y-ticks (and ylims) giving, (ymin, ymax, step) for each of the above channels (0: default)
|
||||
CHANNEL_TICKS:
|
||||
- [-10, 50, 10]
|
||||
- [1, 5, 1]
|
||||
- [1, 5, 1]
|
||||
- [9, 15, 1]
|
||||
|
||||
# Factor for channel to SI-units (for plotting)
|
||||
CHANNEL_UNITS:
|
||||
EX1: 1e-6
|
||||
EX2: 1e-6
|
||||
@ -65,7 +75,6 @@ CHANNEL_UNITS:
|
||||
VEI: 1e-3
|
||||
|
||||
# Transform channel for plotting, perform arithmetic operations in given order, e.g.: PBox EX1 V to deg C: 20 * x -20
|
||||
# optional!
|
||||
CHANNEL_TRANSFORM:
|
||||
EX1:
|
||||
- ["*", 20]
|
||||
|
Loading…
Reference in New Issue