134 lines
5.6 KiB
YAML
134 lines
5.6 KiB
YAML
# Parameters file for Surveillance Bot
|
|
datapath: "/data/SDS/" # SC3 Datapath
|
|
networks: ["1Y", "HA"] # select networks, list or str
|
|
stations: "*" # select stations, list or str
|
|
locations: "*" # select locations, list or str
|
|
stations_blacklist: ["TEST", "EREA"] # exclude these stations
|
|
networks_blacklist: [] # exclude these networks
|
|
interval: 60 # Perform checks every x seconds
|
|
n_track: 300 # wait n_track * intervals before performing an action (i.e. send mail/end highlight status)
|
|
timespan: 3 # Check data of the recent x days
|
|
verbosity: 0 # verbosity flag
|
|
track_changes: True # tracks all changes since GUI startup by text highlighting (GUI only)
|
|
warn_count: False # show number of warnings and errors in table
|
|
min_sample: 3 # minimum samples for raising Warn/FAIL
|
|
dt_thresh: [300, 1800] # threshold (s) for timing delay colourisation (yellow/red)
|
|
html_figures: True # Create html figure directory and links
|
|
reread_parameters: True # reread parameters file (change parameters on runtime, not for itself/GUI refresh/datapath)
|
|
|
|
POWBOX:
|
|
pb_ok: 1 # Voltage for PowBox OK
|
|
pb_SOH2: # PowBox channel 2 voltage translations
|
|
-1: {"230V": "PBox under 1V", "12V": "PBox under 1V"}
|
|
1: {"230V": "OK", "12V": "OK"}
|
|
2: {"230V": "OFF", "12V": "OK"}
|
|
3: {"230V": "OK", "12V": "overvoltage"}
|
|
4: {"230V": "OK", "12V": "undervoltage"}
|
|
4.5: {"230V": "OFF", "12V": "overvoltage"}
|
|
5: {"230V": "OFF", "12V": "undervoltage"}
|
|
pb_SOH3: # PowBox channel 3 voltage translations
|
|
-1: {"router": "PBox under 1V", "charger": "PBox under 1V"}
|
|
1: {"router": "OK", "charger": "OK"}
|
|
2: {"router": "OK", "charger": "0 < resets < 3"}
|
|
2.5: {"router": "OK", "charger": "locked"}
|
|
3: {"router": "FAIL", "charger": "OK"}
|
|
4: {"router": "FAIL", "charger": "0 < resets < 3"}
|
|
5: {"router": "FAIL", "charger": "locked"}
|
|
|
|
# Thresholds for program warnings/voltage classifications
|
|
THRESHOLDS:
|
|
pb_thresh: 0.2 # Threshold for PowBox Voltage check +/- (V)
|
|
max_temp: 50 # max temperature for temperature warning
|
|
low_volt: 12 # min voltage for low voltage warning
|
|
high_volt: 14.8 # max voltage for over voltage warning
|
|
unclassified: 5 # min voltage samples not classified for warning
|
|
max_vm_warn: 1.5 # threshold for mass offset (warn), fail)
|
|
max_vm_fail: 2.5 # threshold for mass offset (warn), fail)
|
|
clockquality_warn: 90 # warn level - clock quality ranges from 0 % to 100 % with 100 % being the best level
|
|
clockquality_fail: 70 # fail level
|
|
min_gap: 0.1 # minimum for gap declaration, should be > 0 [s]
|
|
|
|
|
|
# ---------------------------------- Specification of input channels ---------------------------------------------------
|
|
# Currently supported: EX[1-3], VEI, VM[1-3], LCQ
|
|
#
|
|
# For each channel a factor 'unit' for unit conversion (e.g. to SI) can be provided, as well as a 'name'
|
|
# and 'ticks' [ymin, ymax, ystep] for plotting.
|
|
# 'warn' and 'fail' plot horizontal lines in corresponding colors (can be str in TRESHOLDS, int/float or iterable)
|
|
#
|
|
# 'transform' can be provided for plotting to perform arithmetic operations in given order, e.g.:
|
|
# transform: - ["*", 20]
|
|
# - ["-", 20]
|
|
# --> PBox EX1 V to deg C: 20 * x -20
|
|
CHANNELS:
|
|
EX1:
|
|
unit: 1e-6
|
|
name: "PowBox Temperature (°C)"
|
|
ticks: [-10, 50, 10]
|
|
transform:
|
|
- ["*", 20]
|
|
- ["-", 20]
|
|
warn: "max_temp"
|
|
EX2:
|
|
unit: 1e-6
|
|
name: "PowBox 230V/12V (V)"
|
|
ticks: [1, 5, 1]
|
|
warn: [2, 3, 4, 4.5, 5]
|
|
EX3:
|
|
unit: 1e-6
|
|
name: "PowBox Router/Charger (V)"
|
|
ticks: [1, 5, 1]
|
|
warn: [2, 2.5, 3, 4, 5]
|
|
VEI:
|
|
unit: 1e-3
|
|
name: "Datalogger (V)"
|
|
ticks: [9, 15, 1]
|
|
warn: ["low_volt", "high_volt"]
|
|
fail: 10.5
|
|
VM1:
|
|
unit: 1e-6
|
|
name: "Mass position W (V)"
|
|
ticks: [-2.5, 2.5, 1]
|
|
warn: [-1.5, 1.5]
|
|
fail: [-2.5, 2.5]
|
|
VM2:
|
|
unit: 1e-6
|
|
name: "Mass position V (V)"
|
|
ticks: [-2.5, 2.5, 1]
|
|
warn: [-1.5, 1.5]
|
|
fail: [-2.5, 2.5]
|
|
VM3:
|
|
unit: 1e-6
|
|
name: "Mass position U (V)"
|
|
ticks: [-2.5, 2.5, 1]
|
|
warn: [-1.5, 1.5]
|
|
fail: [-2.5, 2.5]
|
|
LCQ:
|
|
name: "Clock quality (%)"
|
|
ticks: [0, 100, 20]
|
|
warn: "clockquality_warn"
|
|
fail: "clockquality_fail"
|
|
|
|
# specify data channels (can be additional to the above). From these channels only headers will be read
|
|
data_channels: ["HHZ", "HHN", "HHE"]
|
|
|
|
|
|
# ---------------------------------------- OPTIONAL PARAMETERS ---------------------------------------------------------
|
|
|
|
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
|
|
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
|
|
add_links:
|
|
# for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
|
|
slmon: {"URL": "../slmon/{nw}_{st}.html", "text": "show"}
|
|
24h-plot: {"URL": "../scheli/{nw}/{st}.png", "text": "plot"}
|
|
|
|
# E-mail notifications
|
|
EMAIL:
|
|
mailserver: "localhost"
|
|
addresses: ["marcel.paffrath@rub.de", "kasper.fischer@rub.de"] # list of mail addresses for info mails
|
|
sender: "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
|
|
stations_blacklist: ['GR33'] # do not send emails for specific stations
|
|
networks_blacklist: [] # do not send emails for specific network
|
|
# specify recipients for single stations in a yaml: key = email-address, val = station list (e.g. [1Y.GR01, 1Y.GR02])
|
|
external_mail_list: "mailing_list.yaml"
|