survBot/parameters.yaml

87 lines
4.3 KiB
YAML

# Parameters file for Surveillance Bot
datapath: "/data/SDS/" # SC3 Datapath
networks: ["1Y", "HA"] # select networks, list or str
stations: "*" # select stations, list or str
locations: "*" # select locations, list or str
channels: ["EX1", "EX2", "EX3", "VEI", "LCQ"] # Specify SOH channels, currently supported EX[1-3], VEI and LCQ
stations_blacklist: ["TEST", "EREA"] # exclude these stations
networks_blacklist: [] # exclude these networks
interval: 60 # Perform checks every x seconds
n_track: 300 # wait n_track * intervals before performing an action (i.e. send mail/end highlight status)
timespan: 7 # Check data of the recent x days
verbosity: 0 # verbosity flag
track_changes: True # tracks all changes since GUI startup by text highlighting (GUI only)
warn_count: False # show number of warnings and errors in table
min_sample: 3 # minimum samples for raising Warn/FAIL
dt_thresh: [300, 1800] # threshold (s) for timing delay colourisation (yellow/red)
html_figures: True # Create html figure directory and links
reread_parameters: True # reread parameters file (change parameters on runtime, not for itself/GUI refresh/datapath)
POWBOX:
pb_ok: 1 # Voltage for PowBox OK
pb_SOH2: # PowBox channel 2 voltage translations
-1: {"230V": "PBox under 1V", "12V": "PBox under 1V"}
1: {"230V": "OK", "12V": "OK"}
2: {"230V": "OFF", "12V": "OK"}
3: {"230V": "OK", "12V": "overvoltage"}
4: {"230V": "OK", "12V": "undervoltage"}
4.5: {"230V": "OFF", "12V": "overvoltage"}
5: {"230V": "OFF", "12V": "undervoltage"}
pb_SOH3: # PowBox channel 3 voltage translations
-1: {"router": "PBox under 1V", "charger": "PBox under 1V"}
1: {"router": "OK", "charger": "OK"}
2: {"router": "OK", "charger": "0 < resets < 3"}
2.5: {"router": "OK", "charger": "locked"}
3: {"router": "FAIL", "charger": "OK"}
4: {"router": "FAIL", "charger": "0 < resets < 3"}
5: {"router": "FAIL", "charger": "locked"}
# Thresholds for program warnings/voltage classifications
THRESHOLDS:
pb_thresh: 0.2 # Threshold for PowBox Voltage check +/- (V)
max_temp: 50 # max temperature for temperature warning
low_volt: 12 # min voltage for low voltage warning
high_volt: 14.8 # max voltage for over voltage warning
unclassified: 5 # min voltage samples not classified for warning
clockquality_warn: 90 # clock quality ranges from 0 % to 100 % with 100 % being the best level
clockquality_fail: 70
# ---------------------------------------- OPTIONAL PARAMETERS ---------------------------------------------------------
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
add_links:
# for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
slmon: {"URL": "../slmon/{nw}_{st}.html", "text": "show"}
24h-plot: {"URL": "../scheli/{nw}/{st}.png", "text": "plot"}
# E-mail notifications
EMAIL:
mailserver: "localhost"
addresses: ["marcel.paffrath@rub.de", "kasper.fischer@rub.de"] # list of mail addresses for info mails
sender: "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
stations_blacklist: ['GR33'] # do not send emails for specific stations
networks_blacklist: [] # do not send emails for specific network
# names for plotting of the above defined parameter "channels" in the same order
channel_names: ["Clock Quality (%)", "Temperature (°C)", "230V/12V Status (V)", "Router/Charger State (V)", "Logger Voltage (V)"] # names for plotting (optional)
# specify y-ticks (and ylims) giving, (ymin, ymax, step) for each of the above channels (0: default)
CHANNEL_TICKS:
- [0, 100, 20]
- [-10, 50, 10]
- [1, 5, 1]
- [1, 5, 1]
- [9, 15, 1]
# Factor for channel to SI-units (for plotting)
CHANNEL_UNITS:
EX1: 1e-6
EX2: 1e-6
EX3: 1e-6
VEI: 1e-3
# Transform channel for plotting, perform arithmetic operations in given order, e.g.: PBox EX1 V to deg C: 20 * x -20
CHANNEL_TRANSFORM:
EX1:
- ["*", 20]
- ["-", 20]