81 lines
3.8 KiB
YAML
81 lines
3.8 KiB
YAML
# Parameters file for Surveillance Bot
|
|
datapath: "/data/SDS/" # SC3 Datapath
|
|
networks: ["1Y", "HA"] # select networks, list or str
|
|
stations: "*" # select stations, list or str
|
|
locations: "*" # select locations, list or str
|
|
channels: ["EX1", "EX2", "EX3", "VEI"] # Specify SOH channels, currently supported EX[1-3] and VEI
|
|
stations_blacklist: ["TEST", "EREA"] # exclude these stations
|
|
networks_blacklist: [] # exclude these networks
|
|
interval: 60 # Perform checks every x seconds
|
|
n_track: 120 # wait n_track * intervals before performing an action (i.e. send mail/end highlight status)
|
|
timespan: 7 # Check data of the recent x days
|
|
verbosity: 0 # verbosity flag
|
|
track_changes: True # tracks all changes since GUI startup by text highlighting (GUI only)
|
|
warn_count: False # show number of warnings and errors in table
|
|
dt_thresh: [300, 1800] # threshold (s) for timing delay colourisation (yellow/red)
|
|
html_figures: True # Create html figure directory and links
|
|
reread_parameters: True # reread parameters file (change parameters on runtime, not for itself/GUI refresh/datapath)
|
|
|
|
POWBOX:
|
|
pb_ok: 1 # Voltage for PowBox OK
|
|
pb_SOH2: # PowBox channel 2 voltage translations
|
|
-1: {"230V": "PBox under 1V", "12V": "PBox under 1V"}
|
|
1: {"230V": "OK", "12V": "OK"}
|
|
2: {"230V": "OFF", "12V": "OK"}
|
|
3: {"230V": "OK", "12V": "overvoltage"}
|
|
4: {"230V": "OK", "12V": "undervoltage"}
|
|
4.5: {"230V": "OFF", "12V": "overvoltage"}
|
|
5: {"230V": "OFF", "12V": "undervoltage"}
|
|
pb_SOH3: # PowBox channel 3 voltage translations
|
|
-1: {"router": "PBox under 1V", "charger": "PBox under 1V"}
|
|
1: {"router": "OK", "charger": "OK"}
|
|
2: {"router": "OK", "charger": "0 < resets < 3"}
|
|
2.5: {"router": "OK", "charger": "locked"}
|
|
3: {"router": "FAIL", "charger": "OK"}
|
|
4: {"router": "FAIL", "charger": "0 < resets < 3"}
|
|
5: {"router": "FAIL", "charger": "locked"}
|
|
|
|
# Thresholds for program warnings/voltage classifications
|
|
THRESHOLDS:
|
|
pb_thresh: 0.2 # Threshold for PowBox Voltage check +/- (V)
|
|
max_temp: 50 # max temperature for temperature warning
|
|
low_volt: 12 # min voltage for low voltage warning
|
|
high_volt: 14.8 # max voltage for over voltage warning
|
|
unclassified: 5 # min voltage samples not classified for warning
|
|
|
|
# ---------------------------------------- OPTIONAL PARAMETERS ---------------------------------------------------------
|
|
|
|
# add links to html table with specified key as column and value as relative link, interpretable string parameters:
|
|
# nw (e.g. 1Y), st (e.g. GR01A), nwst_id (e.g. 1Y.GR01A)
|
|
add_links:
|
|
# for example: slmon: {"URL": "path/{nw}_{st}.html", "text": "link"}
|
|
slmon: {"URL": "../slmon/{nw}_{st}.html", "text": "show"}
|
|
24h-plot: {"URL": "../scheli/{nw}/{st}.png", "text": "plot"}
|
|
|
|
# E-mail notifications
|
|
EMAIL:
|
|
mailserver: "localhost"
|
|
addresses: ["marcel.paffrath@rub.de", "kasper.fischer@rub.de"] # list of mail addresses for info mails
|
|
sender: "webmaster@geophysik.ruhr-uni-bochum.de" # mail sender
|
|
|
|
# names for plotting of the above defined parameter "channels" in the same order
|
|
channel_names: ["Temperature (°C)", "230V/12V Status (V)", "Router/Charger State (V)", "Logger Voltage (V)"]
|
|
# specify y-ticks (and ylims) giving, (ymin, ymax, step) for each of the above channels (0: default)
|
|
CHANNEL_TICKS:
|
|
- [-10, 50, 10]
|
|
- [1, 5, 1]
|
|
- [1, 5, 1]
|
|
- [9, 15, 1]
|
|
|
|
# Factor for channel to SI-units (for plotting)
|
|
CHANNEL_UNITS:
|
|
EX1: 1e-6
|
|
EX2: 1e-6
|
|
EX3: 1e-6
|
|
VEI: 1e-3
|
|
|
|
# Transform channel for plotting, perform arithmetic operations in given order, e.g.: PBox EX1 V to deg C: 20 * x -20
|
|
CHANNEL_TRANSFORM:
|
|
EX1:
|
|
- ["*", 20]
|
|
- ["-", 20] |