[update] add parameter to disable PowBox usage for selected stations

This commit is contained in:
Marcel Paffrath 2024-08-13 16:40:22 +02:00
parent c57763c016
commit 94cac54716

View File

@ -69,6 +69,7 @@ def set_logging_level(params: dict) -> None:
logging.warning(
f'Could not set logging level. Parameter logging_level = {logging_level_str} could not be interpreted.')
return
logging.info(f'Setting logging level to {logging_level_str}')
logging_level = logging_levels.get(logging_level_str.lower())
logging.basicConfig(level=logging_level)
@ -573,8 +574,6 @@ class StationQC(object):
:param nsl: dictionary containing network, station and location (key: str)
:param parameters: parameters dictionary from parameters.yaml file
"""
if status_track is None:
status_track = {}
self.parent = parent
self.stream = stream
self.nsl = nsl
@ -594,6 +593,8 @@ class StationQC(object):
status_track = {}
self.status_track = status_track
self.powbox_active = self.is_pbox_activated_check()
self.start()
@property
@ -645,7 +646,8 @@ class StationQC(object):
send_mail = False
new_error = StatusError(count=count, show_count=self.parameters.get('warn_count'))
if disc:
new_error.set_disconnected()
msg = disc if type(disc) == str else None
new_error.set_disconnected(msg)
current_status = self.status_dict.get(key)
if current_status.is_error:
current_status.count += count
@ -1027,6 +1029,9 @@ class StationQC(object):
def pb_temp_analysis(self, channel='EX1', t_max_default=50, t_crit_default=70):
""" Analyse PowBox temperature output. """
key = 'temp'
if not self.powbox_active:
self.set_pbox_inactive_error(key)
return
st = self.stream.select(channel=channel)
trace = self.get_trace(st, key)
if not trace:
@ -1117,6 +1122,11 @@ class StationQC(object):
def pb_power_analysis(self, channel='EX2', pb_dict_key='pb_SOH2'):
""" Analyse EX2 channel of PowBox """
keys = ['230V', '12V']
if not self.powbox_active:
for key in keys:
self.set_pbox_inactive_error(key)
return
st = self.stream.select(channel=channel)
trace = self.get_trace(st, keys)
if not trace:
@ -1138,7 +1148,11 @@ class StationQC(object):
def pb_rout_charge_analysis(self, channel='EX3', pb_dict_key='pb_SOH3'):
""" Analyse EX3 channel of PowBox """
keys = ['router', 'charger']
pb_thresh = self.parameters.get('THRESHOLDS').get('pb_1v')
if not self.powbox_active:
for key in keys:
self.set_pbox_inactive_error(key)
return
st = self.stream.select(channel=channel)
trace = self.get_trace(st, keys)
if not trace:
@ -1252,6 +1266,10 @@ class StationQC(object):
with each voltage value associated to the different steps specified in POWBOX > pb_steps. Also raises
self.warn in case there are unassociated voltage values recorded.
"""
if not self.powbox_active:
return
pb_thresh = self.parameters.get('THRESHOLDS').get('pb_thresh')
pb_ok = self.parameters.get('POWBOX').get('pb_ok')
# possible voltage levels are keys of pb voltage level dict
@ -1314,6 +1332,13 @@ class StationQC(object):
""" get UTCDateTime from trace and index"""
return trace.stats.starttime + trace.stats.delta * index
def is_pbox_activated_check(self):
return self.station not in self.parameters.get('no_pbox_stations', [])
def set_pbox_inactive_error(self, key):
msg = self.parameters.get('no_pbox_stations')[self.station]
self.error(key, detailed_message=f'PowBox not connected', disc=msg)
class Status(object):
""" Basic Status class. All status classes are derived from this class."""
@ -1381,8 +1406,10 @@ class StatusError(Status):
self.set_error()
self.default_message = message
def set_disconnected(self, message='DCN'):
def set_disconnected(self, message=None):
self.connection_error = True
if not message:
message = 'DCN'
self.message = message
def set_connected(self):