[minor] soft-coded unit factor for channel analysis
This commit is contained in:
parent
03616a2b7b
commit
bc70dc0816
21
survBot.py
21
survBot.py
@ -721,6 +721,15 @@ class StationQC(object):
|
||||
def return_analysis(self):
|
||||
return self.status_dict
|
||||
|
||||
def get_unit_factor(self, channel):
|
||||
""" Get channel multiplier for unit from parameters. If none is specified return 1 """
|
||||
channel_params = self.parameters.get('CHANNELS').get(channel)
|
||||
if channel_params:
|
||||
multiplier = channel_params.get('unit')
|
||||
if multiplier:
|
||||
return float(multiplier)
|
||||
return 1
|
||||
|
||||
def get_last_occurrence_timestring(self, trace, indices):
|
||||
""" returns a nicely formatted string of the timedelta since program starttime and occurrence and abs time"""
|
||||
last_occur = self.get_last_occurrence(trace, indices)
|
||||
@ -765,7 +774,7 @@ class StationQC(object):
|
||||
+ self.get_last_occurrence_timestring(trace, clockQuality_warn)
|
||||
self.status_ok(key, detailed_message=detailed_message)
|
||||
|
||||
# set WARN status for sever warnings in the past
|
||||
# set WARN status for severe warnings in the past
|
||||
if len(clockQuality_fail) > 0:
|
||||
# try calculate number of fail peaks from gaps between indices
|
||||
n_qc_fail = self.calc_occurrences(clockQuality_fail)
|
||||
@ -785,7 +794,7 @@ class StationQC(object):
|
||||
trace = self.get_trace(st, key)
|
||||
if not trace:
|
||||
return
|
||||
voltage = trace.data * 1e-3
|
||||
voltage = trace.data * self.get_unit_factor(channel)
|
||||
low_volt = self.parameters.get('THRESHOLDS').get('low_volt')
|
||||
high_volt = self.parameters.get('THRESHOLDS').get('high_volt')
|
||||
|
||||
@ -824,7 +833,7 @@ class StationQC(object):
|
||||
trace = self.get_trace(st, key)
|
||||
if not trace:
|
||||
return
|
||||
voltage = trace.data * 1e-6
|
||||
voltage = trace.data * self.get_unit_factor(channel)
|
||||
thresholds = self.parameters.get('THRESHOLDS')
|
||||
temp = 20. * voltage - 20
|
||||
# average temp
|
||||
@ -870,7 +879,7 @@ class StationQC(object):
|
||||
|
||||
# correct for channel unit
|
||||
for trace in st:
|
||||
trace.data = trace.data * 1e-6 # TODO: Here and elsewhere: hardcoded, change this?
|
||||
trace.data = trace.data * self.get_unit_factor(trace.stats.channel)
|
||||
|
||||
# calculate average of absolute maximum of mass offset of last n_samp_mean
|
||||
last_values = np.array([trace.data[-n_samp_mean:] for trace in st])
|
||||
@ -908,7 +917,7 @@ class StationQC(object):
|
||||
if not trace:
|
||||
return
|
||||
|
||||
voltage = trace.data * 1e-6
|
||||
voltage = trace.data * self.get_unit_factor(channel)
|
||||
if self.verbosity > 1:
|
||||
self.print(40 * '-')
|
||||
self.print('Performing PowBox 12V/230V check (EX2)', flush=False)
|
||||
@ -931,7 +940,7 @@ class StationQC(object):
|
||||
if not trace:
|
||||
return
|
||||
|
||||
voltage = trace.data * 1e-6
|
||||
voltage = trace.data * self.get_unit_factor(channel)
|
||||
if self.verbosity > 1:
|
||||
self.print(40 * '-')
|
||||
self.print('Performing PowBox Router/Charger check (EX3)', flush=False)
|
||||
|
Loading…
Reference in New Issue
Block a user